Abstract
In this study, micro-computed tomography (CT) is utilized to detect defects of Ti-6Al-4V specimens fabricated by selective laser melting (SLM) and electron beam melting (EBM), which are two popular metal additive manufacturing methods. SLM and EBM specimens were fabricated with random defects at a specific porosity. The capability of micro-CT to evaluate inclusion defects in the SLM and EBM specimens is discussed. The porosity of EBM specimens was analyzed through image processing of CT single slices. An empirical method is also proposed to estimate the porosity of reconstructed models of the CT scan.
Recommended Citation
Gong, Haijun, Venkata Karthik Nadimpalli, Khalid Rafi, Thomas Starr, Brent Stucker.
2019.
"Micro-CT Evaluation of Defects in Ti-6Al-4V Parts Fabricated by Metal Additive Manufacturing."
Technologies, 7 (2): MDPI.
doi: 10.3390/technologies7020044 source: https://www.mdpi.com/2227-7080/7/2/44/xml